Weidmuller PT 100/4 signal conditioners for current output Bedienungsanleitung Seite 15

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 18
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 14
33
7 Notes on CE labelling of WAVESERIES modules
WAVESERIES modules, that carry CE-labelling, fulfil the requirements
of the EU-Guidelines 89/336/EU “electromagnetic compatibility” and
the therein listed harmonised European Norms (EN).
The declarations of conformity are, in accordance with the above-
mentioned EU-Guideline, Article 10, held at the following address
for the r elevant authorities:
Weidmüller Interface GmbH & Co.
Postfach 3030
32720 Detmold
8 Technical data
Input
Sensor types PT 100/4 Select C accor ding to DIN
IEC 751
Input curr ent 1.35 mA ... 1.45 mA ... 1.60 mA
Connection type selection using DIP switches
Conductor r esistance 50 (3- and 4-wir e connection)
Influence of conductor
resistance max. ± 0.005 °C/ for 3- and 4-wir e
connection
Input range -200 ... +800 °C adjustable using
DIP switches
Offset input range up to +25 % possible