Weidmuller WI-MOD-E-G Bedienungsanleitung Seite 5

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 28
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 4
5
900 MHz Unidirectional Transmitter/Receiver Units—Product Data
WI-I/O 9-L-T
Transmitter
WI-I/O 9-L-R
Receiver
Technical Data
Transmitter Inputs:
Digital:
Pulse:
Analog:
“floating” differential input:
resolution
accuracy
Thermocouple
Accuracy
Receiver Outputs
Digital
Analog
resolution
accuracy
Comms-Fail
Fail-safe
Power Supply
Power consumption @12VDC
Analog loop supply internally generated
Internal monitoring of supply low voltage status
Power consumption increases for pulse inputs > 10Hz.
Serial Port
General Data
Operating Temperature
Humidity
Approvals
Mounting
LED indication: Transmitter Unit
LED indication: Receiver Unit
frequency hopping spread spectrum
Transmit power
Maximum line of sight range
Antenna connector
Dimensions mm (in)
Configuration
Diagnostics
Ordering Data
two inputs, suitable for voltage free contacts / NPN,
or voltage input 0-1 VDC on / >3 VDC off
max rate 10 Hz, 50 msec on time.
Pulse counted as 16 bit register.
0-20 mA (4-20mA, 0-10mA)
16 bit
< 0.1 %
Millivolt (-100mV to +100mV), J, K or T type linearization with
on-board cold-junction compensation
greater than 1°C
9-30 VDC
Receiver 100mA, Transmitter 40mA quiescent,
during radio transmission (50 msec) 300mA
24VDC 30mA
may be transmitted as an “input” (Transmitter unit only)
RS232 RJ45 female DCE, used for configuration
and diagnostics
-40 to 60°C (-40 to 140°F)
0 - 99% RH
FCC Part 15.247, RS210, CSA Class 1 Div 2
DIN-rail mounting
Power/OK, Radio TX , DIN1, DIN2, Analog Setpoint status
902-928MHz, sub-bands available
1W
20 miles (4W ERP), 15km (1W ERP); 3000 ft / 1000 m in
obstructed industrial environments. Radio distances can be
increased by up to 5 intermediate repeater units.
Each transmission may be configured to be sent 1 to 5 times.
SMA connector for antenna or coaxial cable connection.
100 x 22 x 120 (3.9 x 0.9 x 4.7)
User configuration via serial port. Unidirectional units can be
configured to network with Multi-I/O and Gateway units.
Diagnostics features - read input values, write output values,
radio signal strength, monitor communication messages.
Type Part No.
WI-I/O 9-L-T 6720005005
three relay contact outputs, 260V 1A
0-20mA
12 bit
0.10%
Internal status based on configurable time-out value. Comms-
fail status can be configured to a local output.
On “comms-fail”, outputs user-configurable as retained (last
correct value) or reset (fail-safe)
9-30 VDC
Receiver 100mA, Transmitter 40mA quiescent, during radio
transmission (50 msec) 300mA
24VDC 30mA
RS232 RJ45 female DCE, used for configuration
and diagnostics
-40 to 60°C (-40 to 140°F)
0 - 99% RH
FCC Part 15.247, RS210, CSA Class 1 Div 2
DIN-rail mounting
Power/OK, Radio RX, DO1, DO2, DO3, Communications Fail.
902-928MHz, sub-bands available
1W
20 miles (4W ERP), 15km (1W ERP); 3000 ft / 1000 m in
obstructed industrial environments. Radio distances can be
increased by up to 5 intermediate repeater units.
Each transmission may be configured to be sent 1 to 5 times.
SMA connector for antenna or coaxial cable connection.
100 x 22 x 120 (3.9 x 0.9 x 4.7)
User configuration via serial port. Unidirectional units can be
configured to network with Multi-I/O and Gateway units.
Diagnostics features - read input values, write output values,
radio signal strength, monitor communication messages.
Type Part No.
WI-I/O 9-L-R 6720005006
Seitenansicht 4