Weidmuller IE-ARM-U-OSPF Mini Router Bedienungsanleitung Seite 17

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 22
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 16
17
RRSS--223322 iinntteerrffaaccee ffoorr tthhee ""EExxtteerrnnaall"" mmooddee
The device is prepared for operation of an additional RS-232 interface. Communication channels using
this interface will be set up upon request.
FFuunnccttiioonnaall eeaarrtthhiinngg ooff tthhee MMiinnii--RRoouutteerr
For functional earthing, make a connection between the "Functional earth" terminal on bottom side of
the router and the equipotential bonding of the control cubicle.Make sure that the cross-section of the
interconnecting line does not exceed 4 mm2 (AWG12)
22..66 PPoowweerr ssuuppppllyy
Supply voltage 10 ... 35 V DC / 10 ... 24 V AC
Power (max) 4 W / 6 VA
CCaauuttiioonn
Insecure outputs. Operations on the Mini-Router only realise by qualified
employees. Use a power supply unit according to DIN EN 60742 (VDE 0551).You
secure all electrical outputs.